ABC200-10XXG Data Sheet
12VDC, 24VDC, 48VDC
Output
3 ABSOLUTE MAXIMUM RATINGS
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability,
and cause permanent damage to the supply.
Parameter
V i maxc
Max continuous input
Conditions / Description
Continuous
Transient, 60 ms
Min
Nom
Max
264
300
Unit
VAC
VAC
4 ENVIRONMENTAL AND MECHANICAL
Parameter
Conditions / Description
Min
Nom
Max
Unit
T A
T Aext
T S
Ambient temperature
Extended temp range
Storage temperature
V i min to V i max , I 1 nom , I SB nom
Derated output
Non-operational
-10
+50
-40
+50
+70
+85
°C
°C
°C
Width
50.8
mm
Dimensions
Height
Depth
36.6
101.6
mm
mm
M
Weight
0.2
kg
5 INPUT SPECIFICATIONS
General Condition: T A = -10 to 50°C unless otherwise noted.
Active fan air cooling required: 200 LFM (1 m/s)
Parameter
V i nom
Nominal input voltage
Conditions / Description
Min
100
Nom
Max
240
Unit
VAC
V i
I i max
I i p
Input voltage ranges
Max input current
Inrush current limitation
Normal operating ( V i min to V i max )
At 90 VAC input and max rating
V i nom =115VAC, T = 25°C (see Figure )
90
2.75
264
40
VAC
A rms
A p
V i nom =230VAC, T = 25°C (see Figure 4)
80
F i
PF
Input frequency
Power factor
Normal input, half load and above
47
0.9
50/60
63
Hz
V i on
V i off
Turn-on input voltage 1)
Turn-off input voltage 1)
Ramping up
Ramping down
85
80
87
83
90
85
VAC
VAC
η
T hold
Efficiency
Hold-up Time
V i nom =230VAC, 0.5 ? I x nom , V x nom , T A = 25 °C
V i nom =230VAC, 1.0 ? I x nom , V x nom , T A = 25 °C
After last AC zero point, V O within regulation,
V i = 115 VAC, P x nom
10
89
91
%
ms
1)
The power supply is provided with the hysteresis loop (about 4.5V) during turn-on and turn-off within the ranges.
BCD.G0201 Rev. AA, 04-Feb-2013
Page 3 / 12
www.power-one.com
相关PDF资料
ABC400-1024G OPEN FRAME 3 X 5 24V 400W
ABE50DHFR CONN CARDEDGE 100POS 1MM SMD
ABE50DHHR CONN EDGECARD 100POS 1MM DIP SLD
ABJ3638609 SWITCH TURQ SPST LEAF SILV WIRE
ABL-9.8304MHZ-B2 CRYSTAL 9.8304MHZ 18PF HC49/US
ABLS-8.000MHZ-B2-T CRYSTAL 8.000MHZ 18PF SMD
ABLS-LR-3.2768MHZ-T CRYSTAL 3.2768MHZ 18PF LOW ESR
ABLS2-3.579545MHZ-D4Y-T CRYSTAL 3.579545 MHZ 18PF SMD
相关代理商/技术参数
ABC200-1048G 功能描述:线性和开关式电源 200W 48V 4.25A 2" x 4" RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
ABC200-10XXG 制造商:POWER-ONE 制造商全称:Power-One 功能描述:High efficiency over 91% at 230
ABC201-1005G 功能描述:线性和开关式电源 200W 5V 26A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
ABC201-1012G 功能描述:线性和开关式电源 200W 12V 13.33A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
ABC201-1015G 功能描述:线性和开关式电源 200W 15V 10.66A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
ABC201-1024G 功能描述:线性和开关式电源 200W 24V 6.66A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
ABC201-1030G 功能描述:线性和开关式电源 200W 30V 5.33A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
ABC201-1048G 功能描述:线性和开关式电源 200W 48V 3.33A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度: